SLX

SLX 130 Transducer Installation Instructions (PDF)

SLX 300 Transducer Installation Instructions (PDF)

SLX-PBkt SLX 130 Pipe Mounting Bracket

View of "installed sensor"

T420 4-20 mADC Transmitter Calibration (PDF)

SLX 220 Operation and Maintenance (PDF)

SLX 130-E Operation and Maintenance (PDF)

SLX 130-EIS Operation and Maintenance (PDF)

SLX 130-M Operation and Maintenance (PDF)

SLX 130-MIS Operation and Maintenance (PDF)

Chemical Compatibility Chart

 

ULTRIX 100

Ultrix 100 Ultrasonic Level Transducer Operating Manual

Ultrasonic Terminology

Ultrix Application Questionnaire

Ultrix 100 FAQs

Ultrix 100 Troubleshooting Tips

Comparison of Ultrix 100 to Competitors

 

GPX

GPX 220 Installation and Calibration (PDF)

Using the GPX 220 Simulation Function (PDF)

 

FS 90 / FS 96

Cable Installation Instructions (PDF)

Pipe Installation Instructions (PDF)

Pipe Wall Bracket Installation Instructions (PDF)

 

Station Master® Pump Controller

Station Master® 500

SM502-CF Constant Speed Duplex Pump Controller

SM503-CF Constant Speed Triplex Pump Controller

SM504-CF Constant Speed Quadraplex Pump Controller

SM502-VF Variable Speed Duplex Pump Controller

SM503-VF Variable Speed Triplex Pump Controller

SM504-VF Variable Speed Quadraplex Pump Controller

Station Master® 2000

QuickStart Users Manual

Modbus registers (PDF)  (both)

Station Master® 3000

QuickStart Users Manual

Modbus registers (PDF)  (both)

 

CA-2PDA Pump Controller - Analog Input

CA-2PDA User's Guide (PDF)

 

CD-2R Redundant Pump Controller

CD-2R User's Guide (PDF)

 

CD-3R Redundant Pump Controller

CD-3RB User's Guide (PDF)

 

T420

Model T420 4-20 mADC Transmitter Calibration (PDF)

 

Application Information

Application Drawings

1 - SLX 100-MIS Submersible Level Transducer with a MTL 7187+ Intrinsically Safe Zenner Barrier

2 - Station Master 2000 connected to a SLX 100-E

3 - Station Master 2000 connected to a SLX 100-M

4 - Replacing a Consolidated Electric / US Filter A1000 with a SLX 100-E

5 - SLX 100-MIS Submersible Level Transducer with a MTL 7187+ Intrinsically Safe Zenner Barrier and a panel meter for local level indication.

6 - SLX 100-M Submersible Level Transducer with a panel meter for local level indication.

7 - SLX 100-MIS Submersible Level Transducer with a T420 providing a 2nd 4-20 mA output.  (The SLX may be powered by a Station Master controller, providing a 4-20 mA input to the Station Master, while the T420 senses the signal and provides a separate (scalable) 4-20 mA output to power another loop.)

 

 